01 / Generators
Services / 04 of 08

Backup generation.

Gas · Diesel · Petrol

Gas, diesel and petrol sets: supply, install and changeover for backup you can rely on. Sized against the loads you actually need to hold up.

Quote this → All services

What it covers

5 parts · select one for the full scope
04.1 · Scope of works

Sizing

Generators sized against the loads you actually need to keep on, including motor start-up.

AS/NZS 3010
Quote this →
Included
  1. 01Critical load list agreed with you
  2. 02Running and starting current calculation
  3. 03Fuel type and runtime requirements
  4. 04Noise and placement considerations
  5. 05Single or three phase output
  6. 06Allowance for future load
On completion
  • Recommended size and fuel type
  • Load schedule
  • Itemised quote
04.2 · Scope of works

Portable sets

A safe, permanent connection point, so a portable generator can run the property without leads through windows.

AS/NZS 3010 AS/NZS 3000
Quote this →
Included
  1. 01Weatherproof generator inlet
  2. 02Interlocked or changeover switch at the board
  3. 03Selected circuits wired for backup
  4. 04Lead supplied to suit the generator
  5. 05Earthing arrangement confirmed
  6. 06Labelling and operating instructions
On completion
  • Step-by-step changeover guide
  • Certificate of compliance
04.3 · Scope of works

Fixed standby

Permanently installed standby generation for sites that cannot afford to lose supply.

AS/NZS 3010 AS/NZS 5601.1
Quote this →
Included
  1. 01Supply and install of gas or diesel set
  2. 02Concrete pad and enclosure
  3. 03Fuel connection or tank
  4. 04Automatic start controls
  5. 05Exhaust and clearance compliance
  6. 06Scheduled exercise cycle set-up
On completion
  • Commissioning load test
  • Service schedule
  • Operating manual
04.4 · Scope of works

Changeover switching

Manual or automatic changeover, wired so the generator can never backfeed the network.

AS/NZS 3010 AS/NZS 3000
Quote this →
Included
  1. 01Manual changeover switch or automatic transfer switch
  2. 02Break-before-make isolation
  3. 03Neutral switching arrangement
  4. 04Mains-return detection on automatic units
  5. 05Signage at the main board
  6. 06Functional test in both directions
On completion
  • Changeover test record
  • Labelled switchgear
04.5 · Scope of works

Solar & battery

Generators integrated with solar and battery systems, so they only run when storage runs low.

AS/NZS 4509 AS/NZS 5139
Quote this →
Included
  1. 01Compatibility check with inverter-charger
  2. 02Generator start signal wiring
  3. 03Charge settings and source priorities
  4. 04Auto start on low battery
  5. 05Hybrid and off-grid integration
  6. 06System test across all sources
On completion
  • Integrated system settings
  • Operating guide
Typical jobs

A rural property that loses supply in storms. A site that needs cold rooms and pumps to keep running.

What we look at first
Critical loads What has to stay on when the grid goes.
Fuel Gas, diesel or petrol, and what is already on site.
Switching Manual or automatic changeover.