01 / Rural & farm
Services / 06 of 08

Rural & farm electrical.

Sheds · Pumps · Long runs

Sheds, pumps, long runs and off-grid power for properties past the last pole.

Quote this → All services

What it covers

4 parts · select one for the full scope
06.1 · Scope of works

Sheds & workshops

Power, lighting and three phase supply for sheds and workshops, built to handle machinery.

AS/NZS 3000 AS/NZS 3008.1.1
Quote this →
Included
  1. 01Sub-mains from the house or supply point
  2. 02Sub-board with RCD protection
  3. 03Three phase outlets for machinery
  4. 04LED high-bay lighting
  5. 05Welder and compressor circuits
  6. 06Weatherproof outlets and isolators
On completion
  • Sub-board schedule
  • Certificate of compliance
06.2 · Scope of works

Pump control

Bore, transfer and irrigation pumps wired with the right protection and controls.

AS/NZS 3000
Quote this →
Included
  1. 01Dedicated pump circuit
  2. 02Motor starter and overload protection
  3. 03Float and pressure switch controls
  4. 04Timers and irrigation controllers
  5. 05Weatherproof enclosures
  6. 06Solar pump options
On completion
  • Control wiring diagram
  • Test results
06.3 · Scope of works

Long runs

Underground and overhead runs sized for voltage drop over distance.

AS/NZS 3008.1.1 AS/NZS 3000
Quote this →
Included
  1. 01Voltage drop calculation
  2. 02Cable sized for length and load
  3. 03Trench depth and marker tape
  4. 04Conduit and pits
  5. 05Private pole and overhead options
  6. 06Route recorded for future reference
On completion
  • Cable calculation on record
  • Route map of buried cables
06.4 · Scope of works

Stand-alone power

Where the grid is not worth the trench, a stand-alone system of solar, battery and generator.

AS/NZS 4509 AS/NZS 5139
Quote this →
Included
  1. 01Load and autonomy assessment
  2. 02Solar array and battery bank
  3. 03Off-grid inverter-charger
  4. 04Backup generator integration
  5. 05Remote monitoring
  6. 06Cost compared against grid connection
On completion
  • System design and sizing
  • Operating guide
  • Service schedule
Typical jobs

Power run out to a new shed 300 metres from the house, with the pump on its own protected circuit.

What we look at first
Distance Length of the run and the trench route.
Loads Motors, pumps and welders.
Supply What the pole or existing board can carry.

Quote your property.

Request a call back →

Tell us the site and what you want powered. We come back with an itemised price and a date.

EC16867  ·  PL 11344  ·  GF 24561  ·  S6164924  ·  Public liability insured to $20,000,000 with QBE